Single-split-outdoor units

Panasonic air conditioner outdoor unit split Z CU-Z25UBEA R32

Order No.: 758.1493
Manufacturer number: CU-Z25UBEA
Manufacturer: Panasonic

To previous product 758.1225

More in this category: Single-split-outdoor units

Loading

One click to the most important information:

Description

Compatible with: Cassette, concealed duct unit and standing chest
Weather-resistant steel housing on non-twisted base frame. Condenser made from Cu pipe with pressed on aluminium fins. Rotary piston compressor for extremely quiet and energy-saving operation. Frequency-regulated compressor ...

Compatible with: Cassette, concealed duct unit and standing chest
Weather-resistant steel housing on non-twisted base frame. Condenser made from Cu pipe with pressed on aluminium fins. Rotary piston compressor for extremely quiet and energy-saving operation. Frequency-regulated compressor motor with vibration insulated. Expansion valve for adjusting the amount of refrigerant. Quiet-running axial fan, directly driven, electronically balanced, with integrated winding protection.
 

show more


Features

  • Passend für folgende Innengeräte: Kassette-, Kanalgerät und Standtruhe
  • Wetterfestes Stahlblechgehäuse auf verwindungsfreiem Grundrahmen
  • Verflüssiger aus CU-Rohr mit aufgepressten Aluminium-Lamellen
  • Rollkolbenkompressor für besonders leisen und energiesparenden ...
  • Passend für folgende Innengeräte: Kassette-, Kanalgerät und Standtruhe
  • Wetterfestes Stahlblechgehäuse auf verwindungsfreiem Grundrahmen
  • Verflüssiger aus CU-Rohr mit aufgepressten Aluminium-Lamellen
  • Rollkolbenkompressor für besonders leisen und energiesparenden Betrieb.
  • Kompressormotor frequenzgeregel, schwingungsgedämpft.
  • Expansionsventil zurAnpassung der korrekten Kältemittelmenge.
  • Laufruhiger Axialventilator, direkt angetrieben, elektronisch ausgewuchtet, mit integriertem Wicklungsschutz

show more


Suitable products
Indoor unit
Panasonic air conditioner Split cassette CS-Z25UB4EAW 2.5kW without panel (583x583mm)

Panasonic air conditioner Split cassette CS-Z25UB4EAW 2.5kW without panel (583x583mm)

Order No.: 758.2151
Indoor unit
Panasonic air conditioner Split chest CS-Z25UFEAW 2.5kW

Panasonic air conditioner Split chest CS-Z25UFEAW 2.5kW

Order No.: 758.2147
Indoor unit
Panasonic air conditioner split concealed duct unit CS-Z25UD3EAW 2.5kW

Panasonic air conditioner split concealed duct unit CS-Z25UD3EAW 2.5kW

Order No.: 758.2157

Technical data

Dimensions
Width
780 mm
(Erläuterung 5)
Height
542 mm
Depth
289 mm
General information
Type
Single/Multi-Split
Construction
Außengerät
Energy efficiency­class
Heating
A++
explanation 4
Cooling
A++
explanation 4
Refrigerant
R32
Amount of refrigerant
0,88 kg
max. height difference
indoor unit/outdoor unit
15 m
explanation 6
max. pre-filled line length
7,5 m
zul. Leitungslänge
(min. - max.)
3 - 20 m
permissible filling quantity per meter
10 g/m
Electrical Data
Recommended overcurrent relay
16 A
Connection cable
4 x 1,5 mm²
Supply voltage
230/1/50 V/Ph/Hz
max. power consumption
6,2 A
Weight
Weight net
33,0 kg
Performance data
Annual power consumption
Heating
822 kWh/a
standing chest unit
 
879 kWh/a
Cassette unit
 
867 kWh/a
concealed ducted unit
Cooling
111 kWh/a
Standing chest unit
 
139 kWh/a
Cassette unit
 
148 kWh/a
Concealed ducted unit
Nominal heating capacity
3,20 kW
Kassettengerät und Kanalgerät
3,40 kW bei Standtruhengerät
Nominal heating capacity (min. - max.)
0.85 - 5.00 kW
Floor standing
 
0.85 - 4.80 kW
Cassette unit
 
0.85 - 4.60 kW
Channel unit
Nominal cooling capacity
2,50 kW
Nominal cooling capacity (min. - max.)
0.85 - 3.40 kW
Floor standing
 
0.85 - 3.20 kW
Cassette unit
 
0.85 - 3.20 kW
Channel unit
Nominal power consumption
Heating
0.76 kW
Standing chest unit
 
0.79 kW
Cassette unit
 
0.80 kW
Concealed ducted unit
Cooling (min. - max.)
0.52 kW
Standing chest unit
 
0.55 kW
Cassette unit
 
0.58 kW
Concealed ducted unit
SCOP
4,60
Standing chest device
 
4,30
Cassette device
 
4,20
Channel device
SEER
7.90
Standing chest unit
 
6.30
Cassette unit
 
5.90
Concealed ducted unit
Pipe connections
Liquid line
6,35 mm
1/4 inch
Suction gas line
9,52 mm
3/8 inch
Suction line
9,52 mm
3/8 inch
Sound data
Sound pressure level
Heating (high)
47 dB(A)
explanation 4
Cooling (high)
46 dB(A)
explanation 4
Temperature data
Außentemperatur-­Grenzwerte
Heizen
-15 bis +24 °C
Kühlen
-10 bis +43 °C
Note:
  1. EER / COP values are calculated in accordance with EN14511.
  2. Energy efficiency scale from A+++ to D.
  3. The annual power consumption is based on the standards in EU Regulation 626/2011.
  4. Measurement locations - Indoor unit: 1 m in front of the device at a height of 1 m; Outdoor unit: 1 m in front of and behind the unit. The sound level values are based on JIS C 9612. Quiet: Silent running. Low: Lowest configurable fan speed.
  5. 70 mm needs to be added for the pipe connection.
  6. Outdoor unit is placed higher up than the indoor unit.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.

Customers also bought...

Loading

Login now for complete access

To login
Article in stock
Optional article
Panasonic Inbetriebnahme Klima Mono Mono Split bis 7 KW
Commissioning

Panasonic Inbetriebnahme Klima Mono Mono Split bis 7 KW

Order No.: D00.0037