- Panasonic air conditioner outdoor unit Split RB CU-E18RBEA 5.0KW R410A
Panasonic air conditioner outdoor unit Split RB CU-E18RBEA 5.0KW R410A
Description
Grid cassettes are exceptionally well suited to small and medium sized offices, shops and restaurants.
At 60 x 60 cm in size they fit perfectly into suspected Eurogrid ceilings. The cassettes achieve the best energy efficiency currently available in their category and can be used for heating ...
?xml>Grid cassettes are exceptionally well suited to small and medium sized offices, shops and restaurants.
At 60 x 60 cm in size they fit perfectly into suspected Eurogrid ceilings. The cassettes achieve the best energy efficiency currently available in their category and can be used for heating and cooling down to an outside temperature of -10 °C. Special interfaces from Panasonic allow the cassettes to be integrated into GLT systems via KNX, Modbus and EnOcean. The Internet control interface can be used to control the cassette units via smartphone, tablet or PC.
Features
- Can be used in cooling and heating mode down to -10 °C
- External control via Internet, KNX, EnOcean and Modbus
- Simple installation into false ceilings with a Eurogrid (60 x 60 cm)
- 24 hour real time clock with timer
- Configurable higher external static compression for spaces with high ceilings ...
- Can be used in cooling and heating mode down to -10 °C
- External control via Internet, KNX, EnOcean and Modbus
- Simple installation into false ceilings with a Eurogrid (60 x 60 cm)
- 24 hour real time clock with timer
- Configurable higher external static compression for spaces with high ceilings (higher than 2.7 m)
- Pipe lengths up to 20 m
- Condensate pump included (max. delivery head: 750 mm)
- Pre-cut opening for fresh air connection
- Devices can be used with existing R22 refrigerant pipes.
Accessories / Replacement parts
-
Connectivity
-
Remote controls
Technical data
(min. - max.)
Notes
1) The annual power consumption is based on the standards ErP Directive.
2) The preconfigured external static pressure at the maximum air volume is 25 Pa. This setting can be increased using the DIP switch on the control board of the indoor unit.
3) Measurement locations: Indoor unit: 1.5 m beneath the device with 1 m duct on the intake side and 2 m duct on the pressure side; Outdoor unit: 1 m in front of the device at a height of 1.5 m. The measured values are based on EUROVENT document 6/C/006-97.
4) 70 mm need to be added for pipe connections.
5) Energy efficiency scale from A+++ to D.