Outdoor units

Panasonic air conditioner outdoor unit split TKEA CU-Z35TKEA R32 Professional

Order No.: 758.1489
Manufacturer number: CU-Z35TKEA
Manufacturer: Panasonic

To previous product 758.1217

More in this category: Outdoor units

Loading

One click to the most important information:

Description

Thanks to its excellent efficiency values and intelligent controller, the Panasonic TKEA systems guarantee excellent reliability and affordable cooling with external temperatures down to -20 °C. Units are available with power ratings from 2.5 to 7.1 kW.


Features

  • Ganzjähriger Kühlbetrieb bei Außentemperaturen bis -20°C
  • Optimaler Wirkungsgrad selbst bei niedrigen Außentemperaturen
  • Widerstandsfähige Wälzlager
  • Zusätzliche Leitungstemperaturfühler als Einfrierschutz

Suitable products
Indoor unit
Panasonic air conditioner split wall TKEA CS-Z35TKEA 3.5kW professional

Panasonic air conditioner split wall TKEA CS-Z35TKEA 3.5kW professional

Order No.: 758.2142

Technical data

Dimensions
Width
824 mm
explanation 5
Height
619 mm
Depth
299 mm
max. line length
20 m
General information
Energy efficiency­class
Heating
A+
explanation 2
Cooling
A+++
explanation 2
Refrigerant
R32
Kältemittel­einsatzbereich
R32
Amount of refrigerant
1,00 kg
max. height difference
indoor unit/outdoor unit
15 m
explanation 6
max. pre-filled line length
7,5 m
zul. Leitungslänge
(min. - max.)
3 - 20 m
permissible filling quantity per meter
10 g/m
Weight
Weight net
38 kg
Performance data
Design load
Heating
3,60 kW
at -10 °C
Cooling
3,50 kW
Heating output
4,07 kW
at -7°C
Annual power consumption
Heating
1145 kWh/a
explanation 3
Cooling
144 kWh/a
explanation 3
Nominal heating capacity
4,00 kW
Nominal heating capacity (min. - max.)
0,85 - 6,60 kW
Nominal cooling capacity
3,50 kW
Nominal cooling capacity (min. - max.)
0,85 - 4,00 kW
Nominal power consumption
Heating
0,92 kW
Heating (min. - max.)
0,17 - 1,82 kW
Cooling
0,86 kW
Cooling (min. - max.)
0,17 - 1,10 kW
SCOP
4,40
SEER
8,50
Pipe connections
Liquid line
6,35 mm
1/4 inch
Suction gas line
9,52 mm
3/8 inch
Suction line
9,52 mm
3/8 inch
Sound data
Sound pressure level
Heating (high)
50 dB(A)
explanation 4
Cooling (high)
48 dB(A)
explanation 4
Sound power
Heating (high)
65 dB(A)
Cooling (high)
63 dB(A)
Temperature data
Außentemperatur-­Grenzwerte
Heizen
-15 bis +24 °C
Kühlen
-20 bis +43 °C
Note:
  1. EER / COP values are calculated in accordance with EN14511.
  2. Energy efficiency scale from A+++ to D.
  3. The annual power consumption is based on the standards in EU Regulation 626/2011.
  4. Measurement locations - Indoor unit: 1 m in front of and 80 cm below the unit; outdoor unit: 1 m in front of and behind the unit. The sound level values are based on JIS C 9612. Quiet: Silent running. Low: Lowest configurable fan speed.
  5. 70 mm needs to be added for the pipe connection.
  6. Outdoor unit is placed higher up than the indoor unit.
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.

Customers also bought...

Loading

Login now for complete access

To login
Article in stock