- Products
- Bock compressor HAX 4/465-4 400V
Bock compressor HAX 4/465-4 400V
One click to the most important information:
Description
The new energy-efficient “e” models have 2, 4, 6 or 8 cylinders with capacities of 11.4 to 281 m³/h (50 Hz).
The GEA range of semi-hermetic compressors comprises a complete range of performance options using modern and innovative compressor technologies in a 2, 4, 6 or 8 cylinder ...
The new energy-efficient “e” models have 2, 4, 6 or 8 cylinders with capacities of 11.4 to 281 m³/h (50 Hz).
The GEA range of semi-hermetic compressors comprises a complete range of performance options using modern and innovative compressor technologies in a 2, 4, 6 or 8 cylinder design with capacities ranging from 5.4 to 281 m³/h (50 Hz)
The right solution for all applications.
HG (Hermetic Gas-cooled)
Conventional suction gas-cooled compressor design for air conditioning and normal refrigeration applications
HA (Hermetic Air-cooled)
A special GEA design for achieving very low temperatures (R407F) using an air-cooled motor and direct suction on the cylinder.
Universal
- e.g. R134a, R407C, R407F, R404A/R507A
- a compressor design for all common refrigerants used in air conditioning, normal refrigeration and freezing
- maximum operating pressure: 28 bar
- excellent cooling performance with minimal energy consumption
- wide range of applications without requiring any additional cooling
- wear-resistant and durable drive mechanisms
- safe and reliable oil supply
- sturdy valve plate design
- quiet and low vibration
- economical power regulation
- IP65 cabinet for electrical connections
- GEA Compressor Management INT69 GTML Diagnose
- INT69G electronic motor protection
- oil sump heater
- minimal space requirements
Accessories / Replacement parts
-
Control valve for unloaded start system
-
Crankcase heater
-
Oil differential pressure sensor
-
Oil pressure safety switch
-
Oil servicing valve
-
Refrigerator oil
-
Thermal protection thermostat
-
Unloaded start system
Technical data
Notes
- Max. power consumption values are for 50 Hz operation. Multiply these values by a factor of 1.2 for 60 Hz operation. The max. operating current remains the same.
- Max. operating current / max. power consumption when selecting
contactors, leads and fuse contactors: Category AC3. - Tolerance (± 10%) based on the mean voltage range. Other voltages and current types on request
380-420 V Y/YY - 3 - 50 Hz PW
440-480 V Y/YY - 3 - 60 Hz PW
PW = Part Winding, motors for part winding start (no start up reduction required)
- Wind ratio: HGX(HAX)4, HGX(HAX)5, HGX(HAX)6 = 66% / 33%
- Y/Δ designs on request.