Description

The new energy-efficient “e” models have 2, 4, 6 or 8 cylinders with capacities of 11.4 to 281 m³/h (50 Hz).
The GEA range of semi-hermetic compressors comprises a complete range of performance options using modern and innovative compressor technologies in a 2, 4, 6 or 8 cylinder ...

The new energy-efficient “e” models have 2, 4, 6 or 8 cylinders with capacities of 11.4 to 281 m³/h (50 Hz).
The GEA range of semi-hermetic compressors comprises a complete range of performance options using modern and innovative compressor technologies in a 2, 4, 6 or 8 cylinder design with capacities ranging from 5.4 to 281 m³/h (50 Hz)
The right solution for all applications.
HG (Hermetic Gas-cooled)
Conventional suction gas-cooled compressor design for air conditioning and normal refrigeration applications
HA (Hermetic Air-cooled)
A special GEA design for achieving very low temperatures (R407F) using an air-cooled motor and direct suction on the cylinder.
Universal
- e.g. R134a, R407C, R407F, R404A/R507A
- a compressor design for all common refrigerants used in air conditioning, normal refrigeration and freezing
- maximum operating pressure: 28 bar

  • excellent cooling performance with minimal energy consumption
  • wide range of applications without requiring any additional cooling
  • wear-resistant and durable drive mechanisms
  • safe and reliable oil supply
  • sturdy valve plate design
  • quiet and low vibration
  • economical power regulation
  • IP65 cabinet for electrical connections
  • GEA Compressor Management INT69 GTML Diagnose
  • INT69G electronic motor protection
  • oil sump heater
  • minimal space requirements

show more


Accessories / Replacement parts

  • Additional ventilator
    Bock additional fan 230V HG(X)88e
    Order No.: 102.4678
  • Control valve for unloaded start system
    Bock power controller 230V control valve f. HA/HG(X)34, 5-8 LR92
    Order No.: 102.4615
  • Crankcase heater
    Bock oil sump heating-BS 230V replacement 200W f.HG(X)8+88e, F(X)18 80237
    Order No.: 102.4839
  • Intermediate adapter
    Bock intermediate adapter f. pressure shut-off valve f. HG(X)88e
    Order No.: 102.4936
  • Modbus-LAN Gateway
    Bock Modbus-LAN Gateway 230V accessory pack for HA(X)44e+76e+88e
    Order No.: 102.4928
  • Oil differential pressure sensor
    Bock oil differential pressure sensor 230V DELTA-P II f. HG(X)44e-88e
    Order No.: 102.4925
  • Oil differential pressure switch
    Bock oil differential pressure switch BS 230V MP54 f. HG(X)4-7 HG(X) 44e
    Order No.: 102.4668
  • Oil servicing valve
    Bock oil service valve HA/HG(X)4-8 replacement 07946
    Order No.: 102.4913
  • Refrigerator oil
    Fuchs refrigeration machine oil Reniso Triton SE 55 can 1L
    Order No.: 531.0802
  • Fuchs refrigeration machine oil Reniso Triton SE 55 can 10L
    Order No.: 531.0811
  • Thermal protection thermostat
    Bock thermal protection thermostat HA/HG(X)22+34, 4 till 8
    Order No.: 102.4614
  • USB converter
    Bock USB converter for INT69G diagnosis - accessory pack f. HA(X)44e+76e+88e
    Order No.: 102.4929
  • Unloaded start system
    Bock start-up relief 230V HA(X)5/6,HG(X)5-8 AL92 with thermostat wiithout check valve
    Order No.: 102.4606
  • Bock start-up relief BS 230V HA/HG(X)5-8 AL92 with cylinder cover 08981
    Order No.: 102.4824

Technical data

General information
Number of cylinders
8 pcs
Refrigerant
R404A/R507A
R407C
R407F7A R407C/F
Type
HGX88e/2735-4S
Electrical Data
Starting current (locked rotor)
520 / 605 A
PW 1 / PW 1+2
(see explanation 1)
Supply voltage
400/3/50 V/Ph/Hz
(see explanation 2)
max. operating current
141 A
PW 1+2 (see explanation 2)
max. power consumption
77,5 kW
(see explanation 2)
Weight
Weight net
467,7 kg
Performance data
Flow volume
237,9 m³/h
at 1450 rpm-1
Pipe connections
Pressure line
54 mm
 
2 1/8 inches
Suction line
76 mm
 
3 1/8 inches
Volume
Oil charge
ESTER SE55
Oil quantity
9,0 l

Notes

  1. Tolerance (± 10%) based on the mean voltage range. Other voltages and current types on request
    220-240 V Δ / 380-420 V Y-3-50 Hz
    265-290 V Δ / 440-480 V Y-3-60 Hz
    PW = Part Winding, motors for part winding start 1=1. Part winding 2=2. Part winding (unloaded start not required)
    Wind ratio: HG44e, HG56e, HG88e = 50% / 50%
    Y/Δ design on request.
     
  2. Max. power consumption values are for 50 Hz operation. Multiply these values by a factor of 1.2 for 60 Hz operation. The max. operating current remains the same.
    Max. operating current / max. power consumption when selecting contactors, leads and fuses. Contactors: Category AC3