Refrigeration components

Option: Minimum level indicator ENC2-M-1-3 / 4 '' with adapter

Order No.: 115.0022
Manufacturer number: A15-000017
Manufacturer: SCHIESSL

One click to the most important information:

Description

Frequency-regulated GEA Bock power racks work using a Pluscom series semi-hermetic compressor. These units have been specially developed for use in refrigeration systems with variable refrigeration demand. The use of a KIMO frequency converter allows the main compressor to run continuously ...

Frequency-regulated GEA Bock power racks work using a Pluscom series semi-hermetic compressor. These units have been specially developed for use in refrigeration systems with variable refrigeration demand. The use of a KIMO frequency converter allows the main compressor to run continuously while optimally adjusting cooling performance to the current conditions. These devices are therefore an energy-efficient and space-saving alternative to power racks with multiple compressors. The Bock power racks are available in four different performance classes. Refrigerant products R134a, R450A, R513A, R404A, R507A, R448A, R449A can be used. The maximum frequency may need to be adapted for air conditioning applications.
Cooling power is regulated depending on the intake pressure. A KIMO frequency converter is used in combination with a pressure transmitter to control the compressor unit. This is mounted and thermally decoupled on the intake side and records the actual intake pressure value. The frequency converter regulates the cooling power of the rack so that the target value is achieved as closely as possible. The frequency converter is included with the control box and pre-configured for R134a NK. Configuration is input via a keyboard. Only a small number of parameters must be changed to make changes to the refrigerant used and the place of use.

show more


Features

  • optimally adapt compressor performance to changing loads on the refrigeration system
  • very low minimum cooling power
  • optimal temperature and quality for refrigerated goods
  • minimal space needed due to compact design
  • energy saving from better performance control in optimal evaporating ...
  • optimally adapt compressor performance to changing loads on the refrigeration system
  • very low minimum cooling power
  • optimal temperature and quality for refrigerated goods
  • minimal space needed due to compact design
  • energy saving from better performance control in optimal evaporating temperatures
  • standard components mean it is easy to service
  • reduce the installed cooling power and thus the cost of investment by use of coincidence factor
  • simple installation of a heat recovery systems using a common heat exchanger for all areas to be cooled

show more


Scope of delivery

  • Control box with KIMO frequency converter, optionally assembled and wired
  • semi-hermetic compressor from GEA Bock
  • compressor shut-off valves
  • cracnkcase heater
  • fluid collector
  • refrigerant dryer / inspection glass
  • filling valve in the fluid line
  • ball shut-off valve in the pressure, fluid and suction ...
  • Control box with KIMO frequency converter, optionally assembled and wired
  • semi-hermetic compressor from GEA Bock
  • compressor shut-off valves
  • cracnkcase heater
  • fluid collector
  • refrigerant dryer / inspection glass
  • filling valve in the fluid line
  • ball shut-off valve in the pressure, fluid and suction lines
  • pressure transmitter, suction pressure -0.5 - 7 bar
  • pressure transmitter, high pressure 0 - 30 bar
  • combined high/low pressure monitor, type tested
  • low pressure monitor, type tested for emergency operation
  • oil separator with inspection glass and shut-off valve in the return line, with electrical heating

show more