Cooling controller

Danfoss media temperature controller EKC 368 f. KVS-valves 24V 084B7079

Order No.: 231.0534
Manufacturer number: 084B7079
Manufacturer: Danfoss

More in this category: Cooling controller

One click to the most important information:

Description

These regulators and valves are used where there are high demands on the system for cooled unpackaged foodstuffs, e.g. deli counters, cold storage rooms for meat products, cold storage areas for fruit and vegetables, containers, air conditioning systems, etc. A KVS valve is used, the size of ...

These regulators and valves are used where there are high demands on the system for cooled unpackaged foodstuffs, e.g. deli counters, cold storage rooms for meat products, cold storage areas for fruit and vegetables, containers, air conditioning systems, etc. A KVS valve is used, the size of which is determined by the cooling capacity requirements. The valve is fully open in the event of an interruption to cooling or power failure. A solenoid valve is built into the fluid line. This closes if the regulator stops cooling. The Sair sensor is placed in the cold air stream after the evaporator. The regulator can be equipped with data communication so that it can be coupled with other devices in ADAP-KOOL® refrigeration system management systems. This enabled operation, monitoring and data collection from a PC - either on site or remote.

show more


Features

  • Waste is reduced as humidity in the area around the goods is kept as high as possible
  • After levelling out, the temperature is maintained within ±0.5 °C or better
  • Levelling is controlled by an adaptive function that minimises temperature fluctuations
  • Defrost sensor to keep defrosting periods ...
  • Waste is reduced as humidity in the area around the goods is kept as high as possible
  • After levelling out, the temperature is maintained within ±0.5 °C or better
  • Levelling is controlled by an adaptive function that minimises temperature fluctuations
  • Defrost sensor to keep defrosting periods as short as possible
  • PID control
  • Modulating temperature regulation
  • Defrost function, electrical, with hot gas or natural
  • Alarm if the set thresholds are exceeded
  • Relay output for defrost function, solenoid valve, fan and alarm device
  • Input signal that can be used to change the target temperature

show more


Technical data

General information
Original No.
084B7079
Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.

Customers also bought...

Loading

Login now for complete access

To login
Available in another country - please contact your local office