Semi - hermetic

Bitzer Außeneinheit ECOSTAR Schiessl LHV7E/4NE-14.FY

Order No.: A00.0546
Manufacturer number: LHV7E/4NE-14.FY
Manufacturer: Bitzer

To previous product A00.0381

More in this category: Semi - hermetic

One click to the most important information:

Description

The scope of delivery includes the Bitzer ECOSTAR LHV7E/4NE-14.F3Y outdoor unit and a Bitzer oil differential pressure switch. You can find further information in the "Scope of delivery" tab.

The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent ...

The scope of delivery includes the Bitzer ECOSTAR LHV7E/4NE-14.F3Y outdoor unit and a Bitzer oil differential pressure switch. You can find further information in the "Scope of delivery" tab.

The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent efficiency requirements for fans and condenser units. The new ECOSTAR condenser units fulfil these criteria.
Cooling performance can be optimally adjusted as needed using the speed regulator for the compressors and fans. The complete set allows for fast and simple onsite assembly without having to spend time installing additional components. The series has now been extended with new models for freezing applications with increased cooling performance.

Speed-controlled fans

  • low noise, e.g. time-based activation of low sound mode at night

ECOLINE compressors with integrated suction gas cooled frequency converter

  • Extremely reliable
  • high system efficiency
  • low operating costs

“Plug & Play” with integrated, fully programmable controller, wiring and piping

  • Simple onsite installation and configuration

Special features

  • more effective EC fans
  • reduced noise
  • improved condensing efficiency using optimised minichannel compressors
  • high efficiency ECOLINE VARISPEED compressors
  • robust weatherproof metal casing

Key new features:
Auto emergency operation:
• If the event of a sensor fault, the ECOSTAR condenser unit will not shut off
• As soon as the sensor once again begins reporting correct valves, the ECOSTAR condenser unit switches back to normal operation

External release without alarm:
• The alarm relay can be optionally set to remain deactivated where no external release have been given

Externally controlled night mode:
• Night mode limits the compressor frequency and fan speed in order to reduce noise emissions to no more than 45 dB(A).

For more information on the technical data of the compressor, please click here: Compressor 4NE-14.F3Y-40S - 101.7661

show more


Features

show more


Scope of delivery

show more


Accessories / Replacement parts

  • BEST Converter
    Bitzer BEST Converter interface converter with cable set
    Order No.: 101.6616
  • Check valve
    Bitzer check valve 361 200 03
    Order No.: 101.382119
  • Coil
    Bitzer coil AC 220V 343 309 02
    Order No.: 101.1705
  • Display
    Bitzer display LUP200 with heating V3 ECOSTAR 347 920 25
    Order No.: 101.384070
  • Filter dryer
    Bitzer filter dryer 362 101 08
    Order No.: 101.382263
  • Frequency convertor
    Bitzer Frequenzumrichter VARIPACK FOY+39-4
    Order No.: 101.6681
  • Fuse
    Bitzer fuse 345 930 03
    Order No.: 101.381581
  • Master contactor
    Bitzer main contactor 347 922 02
    Order No.: 101.381794
  • Master switch
    Bitzer main switch 347 924 02
    Order No.: 101.381797
  • Oil differential pressure switch
    Bitzer oil differential pressure switch 347 319 11
    Order No.: 101.384138
  • Oil separator
    Bitzer oil separator with check valve mounted f. LHV5E/2DES- to LHV7E/4NE- (355 011 03)
    Order No.: 101.5650
  • Option: Refrigerator oil BSE55, tc > 55 °C
    Bitzer refrigeration oil BSE 55 can 1L 915 111 02
    Order No.: 531.0117
  • Bitzer refrigeration oil BSE 55 can 5L 915 111 04
    Order No.: 531.0119
  • Bitzer refrigeration oil BSE 55 can 10L 915 111 05
    Order No.: 531.0120
  • Bitzer refrigeration oil BSE 55 disposable barrel 205L 915 111 01
    Order No.: 531.0116
  • Pressure sensor
    Bitzer pressure sensor 0-5V ND ECOSTAR 347 314 01
    Order No.: 101.3983
  • Bitzer pressure sensor 0-5V HD ECOSTAR 347 314 02
    Order No.: 101.3984
  • Pressurised gas temperature sensor
    Bitzer pressurised gas overheat protection and sensor ECOSTAR 347 037 01
    Order No.: 101.3988
  • Refrigerator oil
    Bitzer refrigeration oil BSE 32 can 1L 915 110 02
    Order No.: 531.0112
  • Bitzer refrigeration oil BSE 32 can 5L 915 110 04
    Order No.: 531.0114
  • Bitzer refrigeration oil BSE 32 can 10L 915 110 05
    Order No.: 531.0115
  • Bitzer refrigeration oil BSE 32 disposable barrel 205L 915 110 01
    Order No.: 531.0111
  • Temperature sensor
    Bitzer temperature sensor Cold store 5 meters ECOSTAR
    Order No.: 101.4648
  • Bitzer temperature sensor ambient ECOSTAR 347 037 02
    Order No.: 101.3989
  • Transformer
    Bitzer transformer 230/230+24V ECOSTAR 347 921 01
    Order No.: 101.3990

Technical data

Dimensions
Art der Aufstellung
Außenaufstellung
General information
Type
halbhermetisch
Refrigerant
R134a
 
R450A
 
R513A
Type
LHV7E/4NE-14.F3Y
Condensation type
luftgekühlt
Oil charge
BSE32
Option: Refrigerator oil BSE55, tc > 55 °C
Electrical Data
Power consumption
Fan
2x2.1 A
(see explanation 3)
Supply voltage
400/3/50 V/Ph/Hz
see explanation 1
max. operating current
36,0 A
(see explanation 2)
Weight
Weight net
390,0 kg
Performance data
Frequency controlled
Ja
Flow volume
56,25 m³/h
50 Hz at 1450 rpm-1
Pipe connections
Liquid line
22,0 mm
7/8 inch
Suction line
42,0 mm
1 5/8 inches
Collector data
Collector type
F212N3
max. refrigerant charge
23.2 kg
refrigerant=R 134A
 
22.5 kg
refrigerant=R 450A
 
23.1 kg
refrigerant=R 513A
Fan data
Power consumption
2x350 W
(see explanation 3)
Air throughput
10400 m³/h
(see explanation 3)
Number of fans
2 pcs
EC
Compressor data
Speed range
25 bis 87 Hz

Erläuterung

  1. Andere Spannungen und Stromarten auf Anfrage
    380-420 V Y/3/50
     
  2. Bei 400V/3/50 Hz Netzspannung
  3. Daten für maximale Betriebsbedingungen. Lüfter sind drehzahlgeregelt in Abhängigkeit von Betriebsbedingungen.

Effektive Leistungsaufnahme ist deshalb variabel – siehe BITZER Software.

Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading

Login now for complete access

To login
Delivery item. Delivery time on request