Description
Can be used for standard installation. Inspection openings for filters, fans and electrical connections with snap-in closures and hinges. The plastic housing is noise and heat insulated; colour: cream white. Air inlet is via a large grille that folds out for removing the filter. The filter is ...
?xml>Can be used for standard installation. Inspection openings for filters, fans and electrical connections with snap-in closures and hinges. The plastic housing is noise and heat insulated; colour: cream white. Air inlet is via a large grille that folds out for removing the filter. The filter is Nylon and can be regenerated. The condensate tray is made of plastic and insulated to prevent condensation forming.
Features
- Operating modes: Cooling, heating, ventilation, dehumidify,
- Monitoring of the set target temperature,
- Dehumidifying the air in the room uses a special program (unregulated),
- All input values saved in the event of power failure,
- Automatic restart after power failure,
- 24 hour timer (on and/or ...
- Operating modes: Cooling, heating, ventilation, dehumidify,
- Monitoring of the set target temperature,
- Dehumidifying the air in the room uses a special program (unregulated),
- All input values saved in the event of power failure,
- Automatic restart after power failure,
- 24 hour timer (on and/or off), one day timer only,
- Weekly timer (only when using a Standard or Deluxe wired control station),
- Fault diagnostic systems,
- Filter alarm with remaining time display,
- Integrated actuator for remote on/off control (in combination with PREMTBxxx wired remote control only),
- Monitoring of evaporator surface temperature (excessive heat/insufficient heat),
- Communication line to outdoor unit.
Technical data
(Niedrig/Mittel/Hoch)
(Niedrig/Mittel/Hoch)
1. Tested according to EN 14511
2. Performance data based on:
- Cooling: Indoor temperature 27 °C (80.6 °F) DB / 19 °C (66.2 °F) WB; Outdoor temperature 35 °C (95 °F) DB / 24 °C (75.2 °F) WB; Connecting pipe length 7.5 m - Height different: None
- Heating: Indoor temperature 20 °C (68 °F) DB / 15 °C (59 °F) WB; Outdoor temperature 7 °C (44.6 °F) DB / 6 °C (42.8 °F) WB; Connecting pipe length 7.5 m - Height different: None