Semi - hermetic

Bitzer outdoor unit ECOSTAR LHV7E/4DE-5.F1Y

Order No.: 101.8293
Manufacturer number: LHV7E/4DE-5.F1Y
Manufacturer: Bitzer

More in this category: Semi - hermetic

Loading

One click to the most important information:

Description

The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent efficiency requirements for fans and condenser units. The new ECOSTAR condenser units fulfil these criteria.
Cooling performance can be optimally adjusted as needed using the speed regulator for the ...

The new generation of ECOSTAR condenser units
The Ecodesign Directive introduced more stringent efficiency requirements for fans and condenser units. The new ECOSTAR condenser units fulfil these criteria.
Cooling performance can be optimally adjusted as needed using the speed regulator for the compressors and fans. The complete set allows for fast and simple onsite assembly without having to spend time installing additional components. The series has now been extended with new models for freezing applications with increased cooling performance.

Speed-controlled fans

  • low noise, e.g. time-based activation of low sound mode at night

ECOLINE compressors with integrated suction gas cooled frequency converter

  • Extremely reliable
  • high system efficiency
  • low operating costs

“Plug & Play” with integrated, fully programmable controller, wiring and piping

  • Simple onsite installation and configuration

Special features

  • more effective EC fans
  • reduced noise
  • improved condensing efficiency using optimised minichannel compressors
  • high efficiency ECOLINE VARISPEED compressors
  • robust weatherproof metal casing

Key new features:
Auto emergency operation:
• If the event of a sensor fault, the ECOSTAR condenser unit will not shut off
• As soon as the sensor once again begins reporting correct valves, the ECOSTAR condenser unit switches back to normal operation

External release without alarm:
• The alarm relay can be optionally set to remain deactivated where no external release have been given

Externally controlled night mode:
• Night mode limits the compressor frequency and fan speed in order to reduce noise emissions to no more than 45 dB(A).

show more


Features

  • Highlights
    • Alle 13 Typen sind für verschiedene Anwendungen wie Tiefkühlung und Normalkühlung geeignet
    • Verflüssigungssatzregler mit Anzeige
    • Halbhermetischer Verdichter ECOLINE VARISPEED mit integriertem Frequenzumrichter für perfekte Anpassung an den Kältebedarf
    • Zuverlässige ...
  • Highlights
    • Alle 13 Typen sind für verschiedene Anwendungen wie Tiefkühlung und Normalkühlung geeignet
    • Verflüssigungssatzregler mit Anzeige
    • Halbhermetischer Verdichter ECOLINE VARISPEED mit integriertem Frequenzumrichter für perfekte Anpassung an den Kältebedarf
    • Zuverlässige Konstruktion mit bewährten BITZER Produkten
    • Breites Anwendungsspektrum
    • Frequenzumrichter für hohen Wirkungsgrad bei Voll- und Teillast
    • Lange Rohrleitungen und mehrere Verdampfer sind möglich
    • Einfache Installation, Inbetriebnahme und Wartung
    • CE Abnahme nach Modul H gemäß PED 2014/68/EU
  • Produktversionen
    • LHV5E mit einem Ventilator und ECOLINE Verdichter CE2F oder CE3F
    • LHV7E mit zwei Ventilatoren und ECOLINE Verdichter CE3F oder CE4F

show more


Scope of delivery

  • Halbhermetischer Hubkolbenverdichter ECOLINE VARISPEED mit integriertem Frequenzumrichter
  • Ölheizung 200 … 260 V, PTC
  • Luftgekühlter Verflüssiger
    • Minichannel-Design mit 1 Ventilator (nur bei LHV5E/ …)
    • Minichannel-Design mit 2 Ventilatoren (nur bei LHV7E/ …)
    • EC Motoren, ...
  • Halbhermetischer Hubkolbenverdichter ECOLINE VARISPEED mit integriertem Frequenzumrichter
  • Ölheizung 200 … 260 V, PTC
  • Luftgekühlter Verflüssiger
    • Minichannel-Design mit 1 Ventilator (nur bei LHV5E/ …)
    • Minichannel-Design mit 2 Ventilatoren (nur bei LHV7E/ …)
    • EC Motoren, drehzahlgeregelt
  • Wetterschutzgehäuse
  • Flüssigkeitssammler mit Absperrventil
  • Anschluss für Druckentlastungsventil am Sammler / Verflüssiger
  • Schauglas und Filtertrockner in Flüssigkeitsleitung
  • Hoch- und Niederdruckschalter
    • Patronendruckschalter (nicht einstellbar)
    • LHV7E/4NE-14.F3Y: einstellbarer Hochdruckschalter
  • Temperaturfühler
    • für Sauggastemperatur
    • für Druckgastemperatur
    • für Umgebungstemperatur
  • Druckaufnehmer für Hoch- und Niederdruck
  • Komplettverrohrung: Druckleitung, Flüssigkeitsleitung, Saugleitung (isoliert)
  • ECOSTAR-Steuerung: Steuerung der Verdichterdrehzahl und weiterer Funktionen des Aggregats
  • Komplettverdrahtung mit Hauptschalter und Verdichterschütz etc.
  • Ölfüllung BSE32 (Esteröl) für HFC und HFC/HFO Kältemittel tc < 70 °C
  • Bitzer semi-hermetic compressor CE3F 4DE-5.F1Y-40S 400V 25..87Hz - Artikelnummer: 101.7651

show more


Accessories / Replacement parts

  • BEST Converter
    Bitzer BEST Converter interface converter with cable set
    Order No.: 101.6616
  • Check valve
    Bitzer check valve 361 200 03
    Order No.: 101.382119
  • Coil
    Bitzer coil AC 220V 343 309 02
    Order No.: 101.1705
  • Display
    Bitzer display LUP200 with heating V3 ECOSTAR 347 920 25
    Order No.: 101.384070
  • Filter dryer
    Bitzer filter dryer 362 101 08
    Order No.: 101.382263
  • Frequency convertor VARIPACK
    Bitzer frequency converter VARIPACK F1 E-BG C3 ECOSTAR
    Order No.: 101.6670
  • Fuse
    Bitzer fuse 345 930 03
    Order No.: 101.381581
  • Master contactor
    Bitzer main contactor 347 922 02
    Order No.: 101.381794
  • Master switch
    Bitzer main switch 347 924 02
    Order No.: 101.381797
  • Oil differential pressure switch
    Bitzer oil differential pressure switch 347 319 11
    Order No.: 101.384138
  • Option: Refrigerator oil BSE55, tc > 55 °C
    Bitzer refrigeration oil BSE 55 can 1L 915 111 02
    Order No.: 531.0117
  • Bitzer refrigeration oil BSE 55 can 5L 915 111 04
    Order No.: 531.0119
  • Bitzer refrigeration oil BSE 55 can 10L 915 111 05
    Order No.: 531.0120
  • Pressure sensor
    Bitzer pressure sensor 0-5V ND ECOSTAR 347 314 01
    Order No.: 101.3983
  • Bitzer pressure sensor 0-5V HD ECOSTAR 347 314 02
    Order No.: 101.3984
  • Pressurised gas temperature sensor
    Bitzer pressurised gas overheat protection and sensor ECOSTAR 347 037 01
    Order No.: 101.3988
  • Refrigerator oil
    Bitzer refrigeration oil BSE 32 can 1L 915 110 02
    Order No.: 531.0112
  • Bitzer refrigeration oil BSE 32 can 5L 915 110 04
    Order No.: 531.0114
  • Bitzer refrigeration oil BSE 32 can 10L 915 110 05
    Order No.: 531.0115
  • Temperature sensor
    Bitzer temperature sensor Cold store 5 meters ECOSTAR
    Order No.: 101.4648
  • Transformer
    Bitzer transformer 230/230+24V ECOSTAR 347 921 01
    Order No.: 101.3990
  • für Kühlstellentemperatur
    Bitzer temperature sensor ambient ECOSTAR 347 037 02
    Order No.: 101.3989
  • Ölabscheider (Nachrüstung nicht möglich)
    Bitzer oil separator with check valve mounted f. LHV5E/2DES- to LHV7E/4NE- (355 011 03)
    Order No.: 101.5650

Technical data

Dimensions
Art der Aufstellung
Außenaufstellung
Width
1430 mm
Height
1660 mm
Depth
690 mm
General information
Type
halbhermetisch
Refrigerant
R134a
 
R450A
 
R513A
Type
LHV7E/4DE-5.F1Y
Condensation type
luftgekühlt
Oil charge
BSE32
Option: Refrigerator oil BSE55, tc > 55 °C
Electrical Data
Power consumption
Fan
2 x 1,5 A
siehe Erläuterung 3
Supply voltage
400/3/50 V/Ph/Hz
see explanation 1
max. operating current
24,0 A
see explanation 2
Weight
Weight net
330,00 kg
Performance data
Frequency controlled
Ja
Flow volume
26,84 m³/h
50 Hz at 1450 rpm-1
Pipe connections
Liquid line
22,00 mm
7/8 inch
Suction line
35,00 mm
1 3/8 inches
Collector data
Collector type
F212N3
max. refrigerant charge
23,2 kg
R134a (siehe Erläuterung 4)
 
22,5 kg
R540A (siehe Erläuterung 4)
 
23,1 kg
R513A (siehe Erläuterung 4)
Fan data
Power consumption
2 x 350 W
siehe Erläuterung 3
Air throughput
10400 m³/h
siehe Erläuterung 3
Number of fans
2 pcs
EC
Compressor data
Speed range
25 bis 87 Hz
Built-in compressor
4DE-5.F1Y-40S

Notes

  1. Other voltages and current types on request
    380-420 V Y/3/50
     
  2. At 400 V/3/50 Hz mains supply
  3. Data for maximum operating conditionings. Fan speed is regulated depending on the operating conditions.

Effective power consumption is therefore variable - see BITZER software.

Technical modifications reserved. Product images may differ from the actual product and are meant for demonstration purposes only. Absolutely no liability can be assumed for possible indication errors and errors in the manufacturers’ information.
Loading

Login now for complete access

To login
Delivery item. Delivery time on request
Optional article
Bitzer oil differential pressure switch mounted Delta P-II for condensing units LH ..
Oil differential pressure switch

Bitzer oil differential pressure switch mounted Delta P-II for condensing units LH ..

Order No.: 101.3754
Bitzer temperature sensor ambient ECOSTAR  347 037 02
für Kühlstellentemperatur

Bitzer temperature sensor ambient ECOSTAR 347 037 02

Order No.: 101.3989
Bitzer oil separator with check valve mounted f. LHV5E/2DES- to LHV7E/4NE- (355 011 03)
Ölabscheider (Nachrüstung nicht möglich)

Bitzer oil separator with check valve mounted f. LHV5E/2DES- to LHV7E/4NE- (355 011 03)

Order No.: 101.5650